Joseph D.

Joseph D. Job Checkin

Dropped off gift cards for Rachel that were part of the installation agreement. Reviewed equipment but did not complete qa inspection. On qa please investigate maximizing airflow to 3rd level by checking fan speed settings and seeing if adjustments can be made to the dampers 5/22/25 . Performed qa on recently installed trane gas furnace and a/c. Tested system in a/c mode. Refrigerant pressures were good. Inspected all wiring and settings. Adjusted dampers to push more air to the top floors, homeowner said see is happy with the adjustments.


Bill D.

Bill D. Job Checkin

.


Chris B.

Chris B. Job Checkin

TEST - Bad control Board. Need to call supplier to get pricing.


Joseph D.

Joseph D. Job Checkin

Estimate for replacement, Coatesville, PA Provided estimate for replacement of gas furnace and air conditioner for customer based on information provided by service technician.


Tony F.

Tony F. Job Checkin

Estimate


Bill D.

Bill D. Job Checkin

Customer said he and his wife are going to discuss it tonight and hopefully come to conclusion as he knows we’re trying to fill days for next week


Chris B.

Chris B. Job Checkin

TEST


Joseph D.

Joseph D. Job Checkin

Testing Pricebook


Joseph D.

Joseph D. Job Checkin

test


Tony F.

Tony F. Job Checkin

Estimate


Joseph D.

Joseph D. Job Checkin

Completed (3) Heat Tune ups Replaced 16x25x1 filter for Luxaire system above back hallway. Other filters ok. For EACH system Inspected wiring and controls, Measured temperature rise and static pressure. Cleaned flame sensors Checked ignitor ohms. Chexked gas pressures. Exhaust for Carrier unit (main lobby system) pitched backwards on the horizontal after it comes through the roof. There are manual dampers on supply branches for back hallway duct system. The one for Taylor’s office was closed slightly. I opened fully and it now matches the FPM velocity of the supply grille in Brittany’s office. I also noticed that flex is directly attached to take off collar, no hard pipe. Combustion and draft tests: Pass Carrier furnace had very small blow back on smoke test in middle serpentine but I did not notice any increase in excess air when blower motor energized. Systems operating ok at this time


Joseph D.

Joseph D. Job Checkin

Test


Chris B.

Chris B. Job Checkin

Performed QA on Amana Gas Furnace/AC Installation. Reviewed installation with homeowner and went over all questions she had. Tested system in heating and performed combustion test and adjusted gas pressures. Tested each zone separately and together to make sure they were opening/closing properly. Checked bypass damper which was opening when the basement zone was calling by itself. Completed checklist form in system. This install passed the QA Inspection.


Shawn R.

Shawn R. Job Checkin

Zone dampers were wired incorrectly, wired into the open and close terminal not common and close. The dampers are spring open, power close. Corrected and tested system. Dampers are opening and closing as the zone control calls for them.


Luis T.

Luis T. Job Checkin

Installed new Amana furnace and coil in existing aux drain pan. Adapted to existing return and added new 10in bypass damper. Installed new Aprilaire zone panel and made all necessary low voltage connections. Installed new gas piping to shutoff valve and bubble tested. Installed new switch and outlet combo. Installed new condensate pump and new ez trap, tested function. Installed new custom supply plenum and sealed all duct connections. Adapted to existing intake and exhaust. Installed new outdoor unit on leveled stone and pad. Flushed existing lineset, pressure tested past 300 psi and evacuated below 500 microns. added 10 ounces of refrigerant. Tested system in heating and cooling, system working properly. Work area cleaned and install went over with customer.